The new ISO 80369-3 standard for tubing connectors

Benefits of ENFit®

The primary benefit of the ENFit changes are enhanced patient safety and convenience.

Standardized  connectors. Standardized connectors across the industry increasing familiarity in healthcare settings.

Reduce missed connections. The unique connector design helps ensure that enteral tubing and syringes are able to connect only to feeding tubes.

Reduce accidental disconnection. The locking threads help prevent connectors from accidentally pulling away from the tubing.

Reduce leaks the more secure fit the ENFIT connector reduces the potential leaks at connector sites

ENFit Conversion Information & Tools

Implementation Videos

ECRI Webcast
Go Live Team Road to Success
Advocate Meeting

Dates & Schedules

Transition Checklists

ENFit Tool Kits

Includes:
• Interactive Demonstration Model
• ENFit Background
• Medication Preparation Guide
• Patient Discharge Talk Sheets
• Transition Team Manual
• Stay Connected Wristlets & Brochures
• ENFit Samples/Product Bins
• Assembly Instructions

DIMENSIONS:

Closed: 18.5” x 6” x 13”

Set up: 31” x 23” x 13”

Order your kit online

ENFit FAQs

Who developed the proposed new enteral ISO standard connector design?2022-08-18T15:10:47-04:00

The new design was a group effort. AAMI/ISO assembled the ISO 80369–3 Project Group
(PG-3). This group is a global representation of clinicians, practice experts, regulators, and industry participants. Through this open forum, any company interested in the ISO 80369 standard was allowed to participate. The PG-3 group identified, validated, and aligned to a global introduction of the new standard connector to systematically replace all prior enteral nutrition connector systems.

Why are you introducing a new enteral connector?2022-08-18T15:10:23-04:00

The purpose of the new connector is to help reduce the risk of enteral tube feeding misconnections and improve patient safety. The new ISO standard, ISO-80369, has been established for Luer connectors on the nutrition formula end and the patient-access end. There is just one standard nutrition formula connector that will be utilized by all feeding set manufacturers and universally adopted into practice.

Are enteral devices impacted by the Stay Connected initiative?2022-08-18T15:09:35-04:00

Yes, enteral devices, including feeding tubes, administration sets, and enteral syringes are impacted by the initiative. A new enteral-specific ISO standard connector design has been identified and awaits final approval prior to introduction.
New ISO standard connectors have already been implemented and universally adopted
on the nutrition formula end of feeding/administration sets. All enteral device connectors including feeding tubes, administration sets, and medication, flush, and bolus feed syringes are anticipated to comply with the new ISO standard. Enteral-specific syringes will also be required to connect to the new enteral feeding connector for medication, flush, and bolus feed syringes.

What changes are coming to current connectors? And what are the implications of these new standards?2022-08-18T15:09:10-04:00

To reduce the frequency of medical tubing misconnections, an international group of clinicians, manufacturers and regulators, such as the FDA, is collaborating with the International Organization of Standardization (ISO) and the Association for the Advancement of Medical Instrumentation (AAMI) to develop ISO 80369 standards. Unique international standard designs will promote better patient safety and help ensure that connectors for unrelated delivery systems are incompatible. The program that is helping introduce the new standards is called the Stay Connected initiative for using safer connectors.

What is a small-bore connector?2022-08-18T15:08:45-04:00

A small-bore connector is a connector with an inner diameter of less than 8.5mm that is used to link or join medical devices, components, and accessories for the purposes of delivering fluids or gases. A Luer connector is a classic type of a small-bore connector used commonly in the healthcare setting. The current universal design of the Luer connector allows for medical tubing misconnections—connections between unrelated delivery systems that have different intended uses (e.g., vascular, enteral, respiratory, epidural, and intrathecal).

ENFit Education

ENFit Members / Supplier List

ENFit Info Archive

ENFit Connector Changes

ENFit Connector Changes

Important details about the connector design changes taking place for tube feeding.

  • What is ENFit
  • What is the ISO Connection Standard
  • How to implement it
  • What resources are available
  • Training  

New Design Standards Diagram

New Design Standards Diagram

  • REVISED ENFit® Connector Conversion Schedule: U.S. and Canada Legacy Connector Production Phase Out Dates

  • New Design Standards Diagram

  • Frequently Asked Questions

  • ENFIT SUMMIT OVERVIEW

Research & Position Statements

Research & Position Statements

Review the research, literature and GEDSA commentary supporting the ENFit design changes.

Important details about the connector design changes taking place for tube feeding.

REVISED ENFit® Connector Conversion Schedule

U.S. and Canada Legacy Connector Production Phase Out Dates

  • GEDSA Position Statement on FDA Letter to Healthcare Providers

  • ENFit Low Dose Research Poster

  • ENFit Presentation at ESPEN

  • Response to BD Regarding Concerns with ENFit and Dose Accuracy

Title

Go to Top